Lake Road House 2017

Lake Road House

Lake Road House uses key elements of solar passive design to moderate extremes of temperature in Climate Zone 27, and provides a comfortable living environment for a couple planning to scale down.

The home features a rectangular floor plan, with the long axis facing North to capture winter sunlight, but uses a skillion roof overhang to exclude summer sun entering the open plan living area.

To further balance day/night temperature variations, the reverse block construction, and tiled floor areas, provide ample thermal mass to radiate warmth overnight. Winter sun enters the living space through Argon filled double glazed windows reaching almost to the raked ceiling. Tinted double glazing is used on the West facing wall, whereas low-e glass is predominantly featured elsewhere.

The windows are located particularly to channel morning and evening summer breezes into the home, and the rectangular plan aids cross-flow ventilation. Overhead fans in every room also assist airflow.

Internal temperatures stay quite constant due as well to the levels of insulation – R6 in the ceiling and R2.5 and 2.0 in external and internal walls respectively. The Axon and Stria external cladding is also battened out from the timber frame to create another air pocket.

Combined, the design features maintain relatively constant indoor conditions, but an efficient free-standing wood heater, and split-system air conditioner, act as a backup during extreme weather issues.

A 2kw. solar panel system and an evacuated tube solar unit provide power and hot-water to the house , and a 5200 litre tank collects rainwater for kitchen use.

Outdoors an extensive vegetable garden plus fruit trees add to the self-sufficiency and enjoyment of living in this home.

Sustainability Features

Years Open
2017
ENERGY AND WATER EFFICIENT FEATURES
    • Energy efficiency:
    • Efficient lighting
      Draught proofing
      Efficient appliances
    • Passive heating cooling:
    • Shading
      Cross ventilation

    • Passive heating cooling:
    • Alfresco under-roof folding shade system
    • Active heating cooling:
    • Ceiling fans

    • Active heating cooling:
    • Neo wood stove/heater (.7g/kg.emission & 75-80% burn efficiency, Panasonic Econavi 7kw. split system
    • Water heating:
    • Solar hot water (evacuated tube)
    • Water harvesting and saving features:
    • Above ground storage
      Low flow shower heads

    • Above ground rainwater storage Type:
    • Polythene tank
    • Above ground rainwater storage Size
    • 5200 litre
    • Water harvesting and saving
    • Native plant garden
INSULATION SPECIFICATIONS
    • Insulation Type:
    • Ceiling
      Internal and external walls
    • Ceiling Type:
    • Raked & flat ceilings
    • Ceiling Rating:
    • R6
    • Floor Rating:
    • Waffle-pod Slab - P Class rating
    • Internal / External Walls Type:
    • Reverse block and plaster walls. Axon & Stria cladding
    • Internal / External Walls Rating:
    • R2.0 internal and R2.5 external
RENEWABLE ENERGY SPECIFICATIONS
    • Energy star rating:
    • 7.9 Star
    • Renewable energy used:
    • Solar PV grid connect
COSTS AND COST SAVINGS
    • Cost estimate of sustainable home/features:
    • approx. $15000 - $18000 over build cost to include energy saving features.
    • Estimate of annual savings:
    • $1200 - $1500 per yr.
HOUSE DESIGN SPECIFICATIONS
    • House Size
    • 149sqm. internal, 64sqm. alfresco/carport
    • Window and Door Types
    • Double glazing
      Low-e, films
    • Universal Design Features
    • Multi-functional rooms
    • Number of bedrooms
    • 3
    • Number of bathrooms
    • 2
GARDEN AND WASTE REDUCTION
    • Garden / Outdoors
    • Water wise plants
      Edible garden
      Organic
      Composting
      Native plants
      Chickens
Location
Natimuk VIC 3409
    • Housing Type:
    • Standalone House
    • Project Type:
    • New Build
    • Builder
    • Jacorey Pty. Ltd.